Browse all practice questions for the Minnesota Journeyman Sprinkler Fitter Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Minnesota Journeyman Sprinkler Fitter Practice Exam course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • What is the minimum pipe size required for a sensing line?
  • What is the temperature rating range for intermediate sprinkler heads?
  • What materials are typically left for the owner after job completion?
  • What is the minimum size of discharge for a tank used in sprinkler systems?
  • What is the required pitch for dry system branch lines per NFPA 13?
  • What should tie-in drains be used for when installing dry systems?
  • What is the maximum vertical distance above the pipe required for pipe backfill?
  • How long does it typically take for a compressor to fill a dry system?
  • What information must be indicated at the dry pipe or preaction valve regarding low point drains?
  • What is the primary function of a sprinkler system?
  • How often are standpipes typically flowed for maintenance checks?
  • How much pressure should an approved relief valve be set to relieve above system air pressure?
  • What is the maximum unsupported length of any arm over in a system under 100 psi?
  • Dry systems are designed to not exceed what temperature for circulating water?
  • Two acceptable ways to cover sprinklers in paint booths or other areas where sprinklers are subject to be coated in a substance are cellophane bags and ______.
  • How critical is the air supply restoration time for a functioning dry sprinkler system?
  • In a fire pump setup, what is the significance of the 5% volume for sump?
  • In Minnesota, how often is the seismic bracing and pipe hangers required to be inspected?
  • What is the maximum allowable height for sprinkler heads in high ceilings according to standard regulations?
  • What is the minimum distance between residential sprinkler heads?
  • Which of the following sprinkler systems is most likely to be used in a residence?
  • Which type of system utilizes a dry pipe valve?
  • Which of the following areas does not require sprinklers according to NFPA 13R?
  • How frequently must mainline strainers be inspected after any flow condition occurs, including 2" main drain testing?
  • What is the required size of the drain for a 2½ inch standpipe?
  • What is the minimum acceptable capacity for a centrifugal fire pump in relation to the connected fire protection system?
  • What is the smallest orifice size for a head in a rack storage system?
  • What is the required pressure rating for underground components in sprinkler systems?
  • How often should private fire hydrants be inspected?
  • What is the maximum operating pressure for extra hazard storage in a sprinkler system?
  • In the context of fire protection systems, what does NFPA stand for?
  • How many gallons does a dry system typically max out at?
  • Which of the following is the primary function of a backflow preventer?
  • On a dry pipe valve with a 5 to 1 ratio and system psi of 75, what pressure will the valve trip at?
  • What is the maximum time allowed for water flow alarms to sound?
  • For quick response sprinklers that passed testing, when is their next testing due?
  • What is the inspection frequency for kitchen hoods as per regular guidelines?
  • What color are the frame arms on extra high temperature sprinkler heads?
  • In what situation can the 30-minute rule for air pressure restoration be waived?
  • How often should air and water levels be checked on a pressure tank?
  • What type of system operates effectively with or without air pressure?
  • What is the Minnesota state fire protection code?
  • After a dry system has been in service for 3 years, what is required for an air test?
  • What spacing requirement exists for sprinklers in light hazard classifications?
  • Which valve must be present between the air supply and the shutoff valve of the dry system?
  • Within how many feet of the pump suction flange can a control valve be installed in the suction pipe?
  • A minimum of how many inches shall be maintained between the sprinkler deflector and the top of a tier of storage?
  • Which of the following is considered a key element in the design of a fire sprinkler system?
  • Fire pumps must have an automatic relief valve set below which of the following pressures at minimum expected suction pressure?
  • Tread tire storage piles, regardless of storage method, shall not exceed how many feet in the direction of wheel holes?
  • What is the minimum discharge required for a single head design of a residential sprinkler?
  • What is typically required during testing of a fire sprinkler system?
  • What is the maximum length a flex drop can be before it needs support?
  • How should automatic drains in fire pump installations be designed?
  • What is the required pitch for dry system main piping per NFPA 13?
  • What is the minimum clearance between deflector and storage for a standard sprinkler head?
  • What is the maximum distance allowed from the last hanger to the end of a 1 1/4-inch line?
  • What is the purpose of allowing extra time for air pressure restoration in extreme cold?
  • Gauge dials on fire pumps should indicate pressure up to at least twice the rated working pressure of the pump, but not less than what psi?
  • At what temperature is piping for a dry sprinkler system required to be maintained?
  • Where do calculations for a sprinkler system typically start?
  • Who is responsible for verifying sprinkler systems are adequate for what is being stored in the building?
  • What interval is required for the inspection of the interior of steel tanks with corrosion protection?
  • In which section of an installation should a check valve be installed?
  • The air supply for a dry system must restore normal air pressure within how many minutes?
  • When are return bends typically used in plumbing systems?
  • Where should the circulation relief valve on a fire pump be installed?
  • How many hours of experience are required for the MN Test?
  • How often should the interior of steel tanks with no corrosion protection be inspected?
  • Sprinklers shall be inspected from the floor level for corrosion, damage, or other infractions at what intervals per NFPA 25?
  • What is the maximum horizontal spacing for in-rack sprinklers?
  • Standard response sprinklers shall be replaced or sent off for testing at what intervals?
  • For Ordinary Hazard Group 1 sprinkler heads, what is the typical maximum coverage area allowed?
  • What is the permissible distance for head placement from the ceiling in residential applications?
  • What is the maximum distance allowed from the end of a regular branch line to the last hanger for a pipe larger than 1"?
  • What is the minimum spacing required between an upright sprinkler head and a hanger rod?
  • What percentage of portable fire extinguishers can be removed if 1½ inch hose lines are capable of reaching all parts of the building?
  • What is the main drain size required for risers measuring 2½ inches to 3½ inches?
  • A listed device allowed to meet water delivery requirements to the inspector's test connection on a dry system is?
  • According to NFPA standards, what is the type of fire pump you generally cannot use?
  • How many gallons per minute must a fire pump flow to be considered adequate?
  • In which type of sprinkler system does the detection system play a crucial role before water release?
  • What is the maximum size system allowed with a single FDC outlet?
  • How often should the interior of a pressure tank be inspected?
  • What is the maximum coverage area for Ordinary Hazard Group 2 sprinkler heads?
  • At what intervals must a dry system be full-flow trip tested?
  • How many heads can be taken off a cold weather valve?
  • What does NFPA 231C govern?
  • What is the acceptable head orifice size range for sprinklers installed in kitchen hoods and vent ducts?
  • At what intervals should fire protection gauges be replaced or recalibrated?
  • Which NFPA standard relates to the installation of standpipes and hose systems?
  • What must fire pumps be approved for?
  • What type of tank requires inspection annually, regardless of corrosion protection?
  • Where must riser clamps be placed in relation to offsets in the standpipe?
  • What is the density maximum for an extra hazard system classified as having a density less than .25?
  • What type of valve should be located at a low point between the drain valve and the header in the pipeline?
  • Which code universally addresses fire protection?
  • What color bulb indicates high temperature ratings in a sprinkler system?
  • How many heads are required before a Fire Department Connection (FDC) is necessary?
  • When does the license for a journeyman expire each year?
  • For light hazard areas, what is the regulation regarding the number of heads on a branch line?
  • What is the maximum distance allowed from the end of a 1 1/2 inch line to the last hanger?
  • How should pressure sensing lines be positioned relative to the discharge isolation valve?
  • In a deluge system, how are the sprinkler heads activated?
  • In sprinkler systems, what is the common term for horizontal piping that may have sprinkler heads installed directly on it?
  • For a wet system with a trapped section of pipe that exceeds 50 gallons of water, what is the minimum size valve and plug that can be used?
  • Standard pendant sprinklers are allowed on dry systems, but they must be installed on goose necks. The piping must be installed in an area maintained at or above __ degrees.
  • What is the minimum square footage of an ESFR head placement?
  • At what intervals should the interior of steel tanks with no corrosion protection be inspected?
  • What is the minimum height above grade for a fire hydrant?
  • What is the minimum amount of time to close a valve as per regulations?
  • Which type of pipe is not permitted for use under NFPA 13D?
  • What is the flow rate of a master stream?
  • What piping component is known for supplying a vertical line for sprinkler lines?
  • What is the maximum distance that the Fire Department Connection (FDC) must be located after a check valve?
  • What size of predrilled hole is needed for the lag screw?
  • If a sample size of 50-year standard response sprinklers is sent off for testing and passed in 2020, what year would they need to be tested again?
  • What type of system should CPVC pipe and fittings be protected against freezing with?
  • Which type of hazard classification would a restaurant likely fall under for fire sprinkler design?
  • What valve type must be installed in the discharge pipe of a jockey pump?
  • What is the purpose of a branch line in a sprinkler system?
  • What is the required size of the automatic relief valve for a pump of 2500 gpm or smaller?
  • Which NFPA standard covers the installation of sprinkler systems in low-rise residential occupancies?
  • What is the hanger spacing for CPVC pipe 1" in diameter?
  • What is the maximum allowable air leakage for dry systems per week?
  • A pump room and valve enclosure must maintain what minimum temperature to avoid freezing?
  • If you have 3 dry systems in a building sharing an air compressor, how many air maintenance devices are required?
  • What is an acceptable alternative to cellophane bags for covering sprinklers in paint booths?
  • How often should strainers be inspected under normal flow conditions?
  • How many heads must be on a system before supervision is required?
  • What is the maximum distance allowed from the last hanger to the end of a 1" branch line?
  • Which device may be used to meet water delivery requirements to the inspection test valve?
  • Which NFPA standard outlines the Inspection, Testing, and Maintenance of Water-Base Fire Protection Systems?
  • What sprinkler head spacing rule applies to discrepancies in vertical ceiling heights?
  • How many pipe diameters must check valves and backflow prevention devices be located from the pump suction flange?
  • For FDC piping of 3 inches or smaller, how many inlets are required?
  • The distance required from a backflow preventer to the pump suction flange typically ensures what?
  • What materials are acceptable for fire pump and jockey pump pressure sensing lines?
  • What is the nominal orifice size drilled in unions with noncorrosive diaphragms allowed in place of check valves in sensing lines?
  • Service personnel must be qualified to inspect, test, and maintain what type of systems?
  • At what intervals should water storage tank level indicators be tested for accuracy?
  • What is the minimum height above grade that a Fire Department Connection (FDC) shall be placed?
  • All fire hydrants should be tested for a minimum of how long to ensure all foreign materials have cleared?
  • Which type of sprinkler operates best in locations with light hazard classifications?
  • What is the maximum water temperature that can flow through the sprinkler portion of the system?
  • When are local waterflow alarms required?
  • What is NOT considered when determining the distance between hangers for piping?
  • What is the required tamped backfill under and around the pipe in trenches cut through rock?
  • What is the hanger spacing for 1" and 1¼" steel pipe?
  • What is the fine for working in Minnesota without a Minnesota journeyman's license?
  • What is the maximum distance allowed from the end of a 1 1/2 inch or larger copper line to the last hanger?
  • If dry system piping is located in the attic, and the attic is not heated, what is the only type of pendant sprinkler that can be utilized on the system?
  • What is the largest pipe size that can have a threaded union installed on it?
  • What is required for air compressors to function properly in a dry sprinkler system?
  • What is the required hanger spacing for a 2" copper pipe?
  • What is the maximum capacity for a dry system?
  • According to the spare sprinkler head schedule, how many spare heads are needed for a system with 1000 or more heads?
  • Which standard do post indicator valves need to comply with regarding height above the grade?
  • If dry system piping is located in a non-heated attic, what type of sprinkler can be utilized?
  • What is the maximum size pipe that a lag screw rod can support?
  • What distance can a riser supported section span before requiring additional support?
  • What is the minimum diameter size required for the bypass around the check valve?
  • Is a Fire Department Connection (FDC) required for an NFPA 13D type system?
  • What is the hanger spacing for 1½" to 8" steel pipe?
  • At what minimum height should controllers for fire pumps be mounted above the floor?
  • What is the hanger spacing for threadable lightwall steel pipe sized 1" to 3"?
  • What slope must tie-in drain lines maintain for every 10 feet of pipe length?
  • Where should the Fire Department Connection (FDC) be located in a single zone dry system?
  • Ceiling fans over ______ inches in diameter are required to be considered as an obstruction.
  • What is the maximum distance allowed from the end of a 1 1/4 inch copper line to the last hanger?
  • What is the maximum unsupported length of an arm over if the system pressure exceeds 100 psi?
  • What is the approval condition for installing heads in closets according to NFPA 13?
  • For a dry system, the maximum size allowed without a quick opening device is what capacity?
  • Which component generally supplies the entire sprinkler piping network initially?
  • What is the maximum coverage area for Light Hazard sprinkler heads according to NFPA 13?
  • What is the maximum spacing between hangers on 1 1/2" thin wall pipe?
  • How far away should outdoor fire pump units be located from any buildings and other fire exposures?
  • What is the maximum spacing of hangers for 1 1/2" or larger sch. 40 pipe?
  • What is the maximum spacing of hangers on 1 1/2" or larger thin-wall pipe?
  • What is the minimum distance a standard sprinkler head can be to another sprinkler head?
  • In light hazard areas, how many heads are allowed off 1½" pipe?
  • At what pitch does a ceiling no longer qualify as sloped?
  • What is the minimum size pipe that can connect a dry system to the air compressor?
  • In a plastic system, what is the minimum allowable pipe size?
  • A pressure tank for a sprinkler system should be at least how full?
  • What is the maximum number of heads allowed on branch lines on either side of a cross main in a light hazard area?
  • The minimum excess pressure for a relief valve in a dry system should be set at what psi?
  • What level of training should service personnel have for fire protection systems?
  • Where should the main relief valve in a fire pump installation be located?
  • If the length of pipe between the test header and the discharge side of the pump exceeds a certain length, what is the minimum nominal pipe size that must be used?
  • What is the minimum size pipe you are allowed by code to use for a sensing line on a fire pump assembly to the controller?
  • Where are riser clamps on standpipes required in multistory buildings?
  • Quick Response sprinklers in a building are due for testing. The building contains 800 concealed sprinklers, 300 upright sprinklers, and 200 pendant sprinklers, how many sprinklers need to be sent off for testing?
  • What type of sprinkler heads are required if the water temperature exceeds 100°F?
  • Which side of the fire pump discharge should the bypass be located?
  • A relief valve on a dry system located between the compressor and control valve shall be set at how many psi in excess of maximum air pressure in the system?
  • How frequently does a dry system need a full-flow trip test?
  • What temperature rating is required for sprinklers located under skylights?
  • Before water enters a preaction system, which must happen?
  • In hotels and motels, under what conditions does NFPA 13 not require heads in closets?
  • What is the maximum percentage of rated capacity that a centrifugal fire pump should handle as a single demand for fire protection?
  • What is the minimum operating pressure for a sprinkler head?
  • What is the minimum amount of time that a control valve can be closed?
  • What is the minimum suction pressure required for fire pumps to avoid the need for a compound pressure and vacuum gauge?
  • Which NFPA standard provides guidance specifically for residential sprinkler system installations?
  • How many standard head types are typically present in a sprinkler system?
  • What width must Horizontal sidewall sprinklers be installed at above and below a soffit?
  • How long should the water supply be capable of supplying all exposure sprinklers during a fire?
  • What is the minimum pipe size required for Class I and III standpipes?
  • What should be the minimum diameter of a fire pump pressure gauge?
  • If a sample size of quick response sprinklers were sent off for testing and passed in 2020, what year would they be due for testing again?
  • What is the NFPA standard for Water Tanks for Private Fire Protection?
  • Dry-type sprinklers shall be replaced or sent off for testing at what intervals?
  • Where should the pressure sensing line connection for each pump be located in relation to the discharge check valves?
  • What is the notable characteristic of a left-handed fire pump?
  • Standard horizontal sidewall sprinklers shall be located ______ to 6 inches below the deck.
  • In designing a bathroom with a fire sprinkler system, what is the required square footage to be covered?
  • Standpipes shall be supported at which of the following points?
  • What bulb colors correspond to ordinary temperature ratings for sprinkler systems?
  • What is the ratio of water to air required in a dry pipe valve?
  • Protective straps on sprinkler heads may be removed if they are at least how many feet off the floor?
  • How many hours is a bypass around a check valve on a tank required to fill the tank?
  • What is the minimum temperature required for standard pendant sprinklers to be used on dry systems?
  • Which NFPA Standard covers standpipes?
  • What should the pump be installed with when the suction supply to a sprinkler system is sufficient without the pump?
  • What is the maximum length of pipe allowed before a larger nominal pipe size must be used in a test header connection?
  • What is the recommended auxiliary drain size for water trapped greater than 50 gallons?
  • What is the purpose of the contractor's certificate?
  • What is the minimum psi a dry pipe valve is set to trip?
  • When installing an antifreeze system, the solutions shall conform to whom?
  • Are Fire Department Connections (FDCs) required for NFPA 13R systems?
  • What defines a manual standpipe system?
  • At what intervals should an obstruction investigation be performed where piping passes from warm areas into cold areas in pre-action systems?
  • An area of low temperature and low combustibility is considered which type of hazard?
  • When should extra heavy pattern fittings be used?
  • What is the purpose of installing goosenecks on standard pendant sprinklers?
  • In refrigerated spaces maintained below 5° Fahrenheit, how long is the air pressure allowed to be restored after a system activation?
  • What is the recommended maximum distance for spacing between standard spray sprinklers in light hazard areas?
  • How many gauges are required on a dry pipe system?
  • Who is credited with inventing pipe calculations?
  • What type of sprinkler is specifically designed for dry systems in untreated attics?
  • What is the required maximum drop in a smooth flat ceiling before it is considered a wall for sprinkler layout?
  • What is the required inspection frequency for Fire Department Connections (FDCs)?
  • What is the nominal size of the automatic relief valve on a fire pump with a rated capacity not exceeding 2500 gpm?
  • Who is responsible for verifying that sprinkler systems are adequate for what is being stored in a building?
  • Sprinkler piping must be substantially supported from the building structure. What weight must this structure support for water-filled pipe?
  • What is the maximum number of 2" sprinkler heads that can be taken off in scheduled systems?
  • What acceptance tests are required for dry pipe systems?
  • What size of auxiliary drain is required for trapped water over 50 gallons?
  • The required air pressure in a dry system should always be monitored for compliance above which pressure?
  • What type of guards must be used to protect sprinklers subject to mechanical injury?
  • What is the maximum volume of antifreeze allowed in NFPA 13D and NFPA 13R?
  • Standpipe hose valves must be located horizontally, a minimum of 3 feet, and a maximum of ______ feet off the finished floor.
  • If you see a solder link sprinkler with blue paint on the frame arms from the factory, what temperature is this sprinkler?
  • According to NFPA 25, dry-type sprinklers must be tested after an initial period of how many years of service?
  • What type of sprinkler system is associated with storage hazards?
  • What does the light hazard small room rule require in terms of space?
  • How far must a hanger be from a horizontal main after a riser?
  • In light hazard occupancies, how long can the room be before additional sprinklers need to be added, if horizontal sidewall sprinklers are across from each other?
  • What is the maximum water temperature that can flow through the sprinkler portion of the system?
  • What is the minimum curing time required after solvent welding CPVC pipe and fittings, including sprinkler head adapters, before installing sprinkler heads?
  • What pipe size is required for 1¼" hoses for runs between 20' to 80'?
  • What is a common feature of unions used in fire pump sensing lines?
  • How frequently should the dry system's full flow trip be tested?
  • How often should sprinkler heads in commercial cooking equipment and ventilation systems be replaced?
  • What is the minimum valve size required for auxiliary drains on wet systems in freezing temperatures?
  • What is essential for fire pump operation regarding the minimum expected suction pressure?
  • Skylights under how many square feet are not required to have sprinklers installed?
  • What does the term "feed main" refer to in a sprinkler system?
  • What is the required distance between the flanges of the pump suction intake and the elbow and tee for suction requirements to apply?
  • Fire Protection Gauges shall be replaced or recalibrated at what intervals?
  • What is the maximum distance that a pipe can extend from its last support in a sprinkler system?
  • According to NFPA 13, what is the maximum time water can flow without tripping the flow switch?
  • What size of auxiliary drain is required for trapped water between 5 and 50 gallons?
  • What is one purpose of a check valve in a sprinkler system?
  • What is the maximum distance allowed between 1½" hose stations?
  • What is the maximum size of a dry system that can be permitted without a quick-opening device according to Minnesota regulations?
  • Under what condition should sidewall sprinklers not be used?
  • What is the required pressure at the top of the standpipe?
  • When bonding and grounding electrical components to a fire sprinkler system, which practice is not allowed?
  • What is the minimum size pipe allowed for a sensing line on a fire pump to the controller?
  • How far apart should hangers be placed for a 1¼" diameter pipe?
  • Riser clamps are primarily used to provide support for what component in a building's fire protection system?
  • What is the maximum length of hose allowed in hose stations?
  • If an airline feeding a dry or pre-action system runs through the freezer, how long must the removable piece of 1" pipe be for inspection?
  • What distance change necessitates adjustments in the spacing of sprinkler heads due to vertical ceiling height changes?
  • What nominal size should the fittings for fire pump and jockey pump pressure sensing lines be?
  • What is the maximum size of a pipe that can be hung with toggle bolts in sheetrock?
  • What is the maximum distance a sprinkler head shall be down from the deck in an unobstructed construction building?
  • What is the hanger spacing for 1" diameter pipe?
  • What is the standard procedure for performing a hydrostatic test?
  • What is the primary benefit of using a sprinkler system in a building?
  • What should the system air pressure be maintained at in relation to the calculated trip pressure of the dry pipe valve?
  • A wet system with a trapped section of pipe that exceeds 50 gallons of water shall have a minimum of what size valve and plug?
  • What is the minimum size of FDC piping that requires two inlets according to regulations?
  • Sprinkler heads that are color-coded purple indicate what temperature rating?
  • What type of maintenance is crucial for fire sprinkler systems?
  • Which temperature heads should be used for light, ordinary, and extra hazards?
  • Which part of a sprinkler system is considered the most remote?
  • What is the minimum distance required from a sprinkler head to any vertical obstruction?
  • What is the purpose of installing goosenecks for dry pendant sprinklers?
  • What is required to be indicated on a sign at the dry pipe or pre-action valve regarding low point drains?
  • In a suction reservoir, where should a drain pipe discharge to prevent air from being drafted by the pump?
  • If a sample of standard response sprinklers passed testing, when would they be tested again?
  • How far apart must hangers be placed on horizontal piping from a standpipe to a hose valve?
  • How often must standard response sprinklers be retested after their initial replacement?
  • With standard spray sprinklers, obstructions to discharge over how many feet wide require sprinklers to be installed under the obstruction?
  • What is the primary purpose of a Fire Department Connection (FDC)?
  • What is the pressure requirement for class III standpipe systems?
  • What nominal size should the fittings of the pressure sensing lines be?
  • How many pipe diameters away from the pump suction flange must check valves be located in the suction pipe?
  • At what intervals shall anti-freeze systems be tested for the level of freeze protection?
  • What is the largest pipe size that can be hung from a toggle hanger?
  • Why is an eccentric reducer utilized on the suction side of the pump?
  • What is the unsupported length on the end of branch lines from the last hanger location for 1¼" pipe?
  • What is the minimum size of a common drain for sprinkler systems with floor control valves that have 1 1/2" drains?
  • When piping passes through warm areas into cold areas on a pre-action system, an obstruction investigation needs to be performed at what intervals?
  • There are three types of fire pump drivers acceptable to NFPA 25 and NFPA 13, which is not an acceptable fire pump driver?
  • What is the maximum allowable spacing between sprinkler heads in a standard occupancy?
  • What is the maximum distance vertically from the peak that sprinkler heads can be positioned in attics?
  • What is a transfer main that is supplied by the riser or cross main called?
  • What color bulb is required for a head in a heater zone within a 7 ft circle?
  • When inspecting a building with quick response sprinklers over 20 years old, how many sprinklers need to be sent off for testing if there are 800 concealed, 300 upright, and 200 pendant sprinklers?
  • According to NFPA standards, which type of fire pump assembly is not accepted?
  • On wet systems, if a trapped section of pipe holds less than how many gallons, the auxiliary drain must consist of a valve not smaller than 1/2 inch?
  • What size common drain pipe must be installed in a stairwell if the system drains are 1 1/2"?
  • What is the required clearance for materials stored beneath a sprinkler deflector in a storage area?
  • What is the duration of water supply required for NFPA 13D systems?
  • Which types of sprinkler heads can be utilized on dry systems?
  • The air supply on a dry system in a non-refrigerated space must restore normal air pressure within how many minutes?
  • How often should antifreeze system freeze point protection be tested?
  • What type of sprinklers are required in a skylight?
  • What is the maximum distance allowed between sprinkler heads that are located 12'6" apart along a branch line?
  • How does NFPA define "extra hazard" in storage applications?
  • What is the maximum allowable time for an air compressor to fill a dry sprinkler system?
  • How much weight should a hanger be able to support in a sprinkler system?
  • Fire pump pressure gauges with a dial less than how many inches in diameter require a nominal 1/4" gauge valve?
  • Fire Department Connections are required to be a minimum of 18 inches and a maximum of _____ inches off the finished grade.
  • The minimum allowable air pressure for a dry fire protection system is?
  • What is the required pitch for dry systems?
  • What pressures and flows are class II standpipe systems designed for?
  • What is the maximum time allowed for water to reach the inspector's test on a dry pipe system?
  • For multiple adjacent trapped branch pipes in dry systems, tie-in drains should be pitched how many inches per 10 feet?
  • What type of pipe is not acceptable for a standpipe?
  • What is the minimum distance required for a lintel to be considered a compartment?
  • What is the coverage area for ESFR sprinkler heads?
  • What is the typical maximum duration for a hydrostatic test performed on a sprinkler system?
  • What materials are acceptable for constructing sensing lines in fire pumps?
  • How does the air pressure in a dry pipe system typically compare to the system's water pressure?
  • Dry system main piping shall be pitched at ______ per 10 feet.
  • What type of piping is supplied by the riser nipple from the cross main?
  • What is the minimum pipe size required to feed 1½" hose lines for horizontal runs up to 20'?
  • What is the minimum distance a sprinkler head can be from the wall?
  • How many sprinklers must be sent off for testing if a sample size of quick response sprinklers fails the initial testing and are over 20 years old?
  • How far off the bottom must an anti-vortex plate be installed at a minimum?
  • What is the minimum system pressure rating for aboveground components in sprinkler systems?
  • What size pipe is required for a pipe stand that will support 10" pipe?
  • What is the maximum drop in a smooth flat ceiling before you have to consider it a wall for the purpose of sprinkler layout?
  • Pendant and upright sprinklers for residential application shall be positioned so that the deflectors are within how many inches from the ceiling?
  • What is the acceptable temperature classification for sprinkler heads installed near heat ducts?
  • What is the required main drain size for risers that are 4 inches and larger?
  • What is the maximum number of heads you can calculate on an NFPA 13R type system?
  • How long is the minimum run time for a diesel fire pump during testing?
  • What is the maximum distance horizontally that heads can be out of center in attics?
  • For which size of CPVC pipe is the recommended hanger spacing 6' 6"?
  • How often should water storage tank level indicators be tested for accuracy?
  • Trapped water less than 5 gallons requires what size auxiliary drain?
  • At what distance should sidewall sprinkler head deflectors be located from the finished ceiling?
  • Storage on shelves in closets and other storage arrangements must be maintained at ______ inches below the sprinkler deflector.
  • What pressure and flow are 1½" hose stations designed for?
  • When measuring the distance from a metal pan deck to the sprinkler, if the pan is 3 inches or larger, to where should the measurement be taken?
  • What is the maximum height allowed for a sprinkler head location beneath a non-combustible ceiling?
  • What is an acceptable alternative to using a valve and nipple configuration for auxiliary drainage on dry systems?
  • What is NFPA 13R primarily used for?
  • What is the maximum length a branch line starter piece can be without a hanger?
  • What is the maximum distance between supports of risers in a sprinkler system?
  • What type and size of piping should sensing lines for fire pumps consist of?
  • What type of sprinkler heads should be used for temperatures exceeding 100°F?
  • How frequently must antifreeze systems be tested to ensure freeze point protection?
  • When isolated trap sections of system piping exceed 5 gallons, how many valves must be included in the auxiliary drain?
  • In what scenario do you require intermediate or high temperature sprinkler heads?
  • What is the minimum distance a backflow preventer with butterfly control valves must be installed from the pump suction flange?
  • What is the recommended inspection interval for dry system air pressure?
  • How often should seismic bracing and pipe hangers be inspected from floor level?
  • When adding a new sprinkler system in an existing building, what is one consideration for head placement?
  • When it comes to bonding and grounding electrical components to a fire sprinkler system, what is not allowed on a fire sprinkler system?
  • A sprinkler with blue liquid in the bulb would discharge at what temperature?
  • How often must standpipe valves be inspected?
  • Who should pre-plan the location and access to a fire pump room?
  • Which type of valve is specifically used for controlling the direction of water flow in a fire protection system?
  • Should pump rooms be lighted and heated?
  • What is the minimum pipe size for standpipes that are part of a combined system for completely sprinkled buildings?
  • In dry pipe systems, branch lines must be pitched at least how many inches per 10 ft?
  • At what width soffit must you install a sprinkler above and below a soffit when dealing with horizontal sidewall sprinklers in soffits?
  • What material is commonly used for sprinkler system piping?
  • What is the maximum hanger spacing for copper tube pipe sized ¾" to 1"?
  • What is the replacement or testing interval for quick response sprinklers?
  • What is the term for the main supply line installed parallel to the building's roof structure?
  • When passing through walls, ceilings, or floors of the fire pump room enclosure, the hole for the pipe must be nominally larger than the pipe by what diameter?
  • FDC connections shall be located between which of the following heights above finished ground?
  • Which option is a requirement for bonding on a fire sprinkler system?
  • What is the required minimum connection size for a system pressure gauge in sprinkler systems?
  • What is a key component that should be checked during a monthly churn test?
  • How far apart can residential sprinkler heads be spaced at maximum?
  • Standard response sprinklers must be replaced or tested after how many years of service?
  • What is the minimum clearance between storage and the deflector of large drop sprinkler heads?
  • Which NFPA standard is focused on sprinkler systems in one- and two-family dwellings?
  • What is the inspection interval for the interior of steel water storage tanks with corrosion protection?
  • What is the maximum size pipe that can be supported by drilling holes in the metal pan ceiling?
  • What is the minimum pipe size that can connect the dry system to the air compressor?
  • What is the maximum distance from a hydrant that a FDC can be located?
  • For horizontal piping extending more than 18 inches, what is required?
  • What is the maximum distance allowed from the end of a 1 1/2 inch branch line or larger to the last hanger?
  • In a fire pump system, which type of pipe is acceptable for the pressure sensing lines?
  • What is the maximum number of sprinklers that can be installed on any one pre-action system?
  • Sprinkler piping shall be substantially supported from the building structure which must be able to support?
  • What is the maximum distance allowed from the end of a 1" copper line to the last hanger?
  • Which material is NOT typically used as a freezing protection for CPVC pipes?
  • How often must dry system branch lines be inspected for leaks according to regulations?
  • For a properly functioning fire pump system, what is a common size for the relief valve on larger pumps?
  • What is the lag screw size used for a 6" pipe?
  • What is the minimum required height for fire Department Connection (FDC) connection points?
  • Ceiling pockets do not require sprinklers unless they are over 36" deep and over _____ square feet in size.
  • What is the maximum length between hangers for vertical piping installations?
  • What is the typical maximum coverage area for Extra Hazard sprinkler heads?
  • What is the purpose of a sprinkler system drain valve?
  • What is the maximum allowed time for a compressor to fill up a dry system to its required pressure?
  • Dry system branch lines shall be pitched at ______ per 10 feet.
  • What type of system should utilize pressure relief valves?
  • What size rod is needed for hanging 10 inch and 12 inch pipe?
  • What is the function of a riser nipple in a sprinkler system?
  • Maximum allowable time for air pressure restoration in a dry system is?
  • What is the specified maximum coverage area for Extra Hazard sprinkler heads?
  • Which type of fire pump is dedicated for fire protection services?
  • What is the maximum pressure of a 2½" hose valve on a standpipe system?
  • What is the maximum ceiling temperature for intermediate sprinkler heads?
  • Class III and class I standpipe systems are designed for what pressures and flows?
  • If recalibrating a sprinkler system gauge rather than replacing it, at what percentage off must the gauge be replaced?
  • True or False? Powder driven studs or welded studs must have a coupling to attach to the rods.
  • What is the maximum allowable distance between the ceiling and the deflector of a sprinkler below a non-combustible ceiling?
  • Fuel tanks for fire pumps should have a capacity equal to what formula?
  • How often should mainline strainers be inspected?
  • What is the maximum time for initial water discharge from the system test connection in a dry system?
  • A fire pump must be dedicated to what type of service?
  • What is the typical maximum coverage area for Storage heads?
  • The pressure sensing line connection for each pump must be made where in relation to the pump's discharge check valve?
  • What is the maximum time for initial water discharge from the test connection on a dry system?
  • How long must pipe and fittings be cured before installation of sprinkler heads to prevent damage?
  • According to NFPA 25, sprinklers should be inspected for corrosion and damage at what intervals?
  • What is the primary purpose of ceiling pocket sprinklers?
  • What should the nominal size of an automatic relief valve be for pumps with a capacity of 3000 gpm to 5000 gpm?
  • What must be considered if the ceiling drop exceeds 36 inches during sprinkler layout planning?
  • What type of couplings should be attached to powder driven studs?
  • Standard response sprinklers must be replaced after how many years of service?
  • When system pressure exceeds 100 psi, what is the maximum unsupported distance between the end sprinkler in the pendant position and the closest hanger?
  • What temperature does a solder link sprinkler with blue paint signify?
  • According to NFPA 13, how many residential heads should be calculated?
  • What is the minimum operating pressure for sprinklers serving a storage area with commodities?
  • When can sprinklers be installed with a closed valve?
  • When storing tread tires, what is the maximum height allowed in feet?
  • A sprinkler with red liquid in the bulb would discharge at what temperature?
  • Quick Response Sprinklers shall be replaced or sent off for testing at what intervals?
  • What is the minimum air pressure required for a pressure tank?
  • What is the minimum pitch required for mains in dry pipe systems in non-refrigerated areas?
  • What does NFPA 20 govern in terms of fire protection?
  • Do dry type pendant sprinklers need to be installed on goosenecks in a dry sprinkler system?
  • What is the maximum distance a standpipe can be situated from a hydrant?
  • If an obstruction is wider than 4 ft requiring sprinklers to be installed under it, what is the acceptable distance for adding sprinklers next to the obstruction?
  • When the suction pipe and pump suction flange are not the same size, what should be used to connect them to avoid air pockets?
  • If a gauge is recalibrated, at what percentage deviation does it fail and must be replaced?
  • Which NFPA standard pertains to the installation of sprinkler systems?
  • What is the maximum distance between hangers for 1" schedule 40 pipe?
  • When should mainline strainers be internally inspected?
  • The interval for testing water storage tank level indicators is?
  • What is the inspection frequency for kitchen hoods?
  • According to NFPA 72, what is the maximum time water can flow before the flow switch goes into alarm?
  • When looking at a fire pump motor, if the suction side is on the left, what type of pump is it?
  • What is the name of the plate at the bottom of a tank that stabilizes the stream when a pump is receiving suction supply?
  • How often should diesel fire pumps be run for testing?
  • Sensing lines for fire pumps and jockey pumps must be run separately, and must tie into the pump assembly between the discharge check valve and the ___________?
  • What is the requirement for the installation of sprinkler heads in trash chutes according to fire safety standards?
  • What is the frequency for checking standpipe components?
  • For what purpose is the 3/32" hole in the clapper of the check valve?
  • How often does an electric fire pump need to be operated at rated speed?
  • Why is a check valve with a 3/32" hole in the clapper required in freezer spaces?
  • What is the requirement for sprinkler heads in trash chutes?
  • What method is NOT allowed for supervising open valves on a backflow prevention device?
  • What is the minimum size pipe allowed in a dwelling unit for sprinkler systems using steel pipe?
  • The automatic relief valve for fire pumps with a rated capacity not exceeding how many gpm must have a nominal size of 3/4 inch?
  • For encapsulated storage, what is the maximum horizontal spacing for sprinklers?
  • What is the regular operation time for electric fire pumps during testing?
  • Sprinklers in a rack shall discharge not less than how many psi for all classes of commodities?
  • What pressure is typically associated with 1½" hose stations in a sprinkler system?
  • What diameter should a trip test connection or manifold pipe have at minimum?
  • What is the maximum length between hangers for 1 inch sch 40 pipe?
  • What is the maximum length of nipple rising from the tee to supply pendant heads below in a new suspended ceiling?
  • What type of hazard is associated with areas where flammable liquids are stored?
  • On fire pump gauges, the dial must indicate pressure to at least twice the rated working pressure but not less than how many psi?
  • What is the primary purpose of a jockey pump in a fire suppression system?
  • What is the maximum square footage that a standard spray sprinkler can be spaced in a light hazard occupancy?
  • What is the minimum number of manual and automatic starts required during fire pump acceptance testing?
  • The circulation relief valve on a fire pump should be installed on which side of the pump?
  • According to NFPA 13, how should branch lines be pitched?
  • When tightening the arms of sprinkler heads, in which direction should they be aligned?
  • What is the main drain size for risers up to 2 inches in size?
  • Which component indicates the pressure near the discharge casting of a fire pump?
  • For a water storage tank, the distance between the floor and any part of the tank shall be at least how many feet?
  • What must not exceed 150% of the centrifugal fire pump's rated capacity?
  • What is the maximum length a sprinkler label is allowed on our sprinkler pipe?
  • What typically marks the transition from underground piping to interior piping in a sprinkler system?
  • What is a common indicator that a sprinkler is rated at 286°F?
  • What is the testing interval for dry-type sprinklers after they have been in service for 50 years and passed their previous test?
  • What is required to prevent accidental activation of a dry pipe valve?
  • All fire hydrants shall be opened fully and flowed until all foreign material has cleared or for a minimum of 1 minute at what intervals?
  • Which organization sets the standards for fire sprinkler systems?
  • Which component could potentially introduce issues if proper bonding and grounding practices are not adhered to?
  • Where does a Fire Department Connection (FDC) need to be located?
  • How many spare sprinkler heads are required for systems with 300 to 999 heads?
  • Dry-type pendant sprinklers on a dry sprinkler system do not need to be installed on goosenecks. True or False?
  • At what height should post indicator valves be set above the final grade?
  • How many feet should there be between a standpipe and five hydrant FDC?
  • Where must sensing lines for the fire pump and jockey pump tie into the system?
  • What is the minimum operating pressure of an in-rack sprinkler head?
  • How often should dry systems be checked for air leakage?
  • Post indicator valves should be located at least how many feet away from a building?
  • What type of sprinkler head is required if it is located above a heat duct within a 7' radius?
  • What is the maximum sprinkler spacing for an extra hazard system with a density greater than or equal to .25?
  • What is the inspection interval for water storage tanks with corrosion protection?
  • In dry pipe systems, how should branch lines be pitched in nonrefrigerated spaces?
  • What is the accepted maximum length for copper lines before requiring a hanger?
  • What is the maximum square footage of a standard spray sprinkler in an ordinary hazard occupancy?
  • After passing the initial testing, when should dry-type sprinklers next be tested?
  • According to the Minnesota State Fire Code, how often should dry systems be checked for air leakage?
  • An approved relief valve on a dry system must relieve pressure at least how many psi above the system air pressure?
  • In refrigerated spaces maintained below 5 degrees, the air pressure must be restored within how many minutes?
  • If a building has a blend of different types of sprinklers including both dry-type and quick response, which type's intervals for testing would generally be shorter?
  • If standing behind a fire pump motor and looking toward the fire pump, the suction side of the pump is on the left, what is this pump?
  • How often must lateral sway bracing be installed for feed and cross mains?
  • In scheduled systems, what is the maximum number of 1" sprinkler heads that can be taken off?
  • When should the interior of steel water storage tanks be examined if they do not have corrosion protection?
  • How much clearance is required around pipes in a pump house when they pass through walls?
  • What is the required setting for an automatic relief valve installed with a fire pump?
  • What is the focus of NFPA 14?
  • What is NOT a typical installation requirement for backflow preventers according to standard practice?
  • If the minimum pump suction pressure is below what psi, a compound pressure and vacuum gauge must be used?
  • If a sample size of dry-type sprinklers were sent off for testing and passed in 2020, what year would they need to be sent off for testing again?
  • What is the minimum diameter of a trip test connection or manifold pipe required?
  • What is the required height for a hose valve location above the floor?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy